ION-TOF ToF-SIMS NCS
LOCATION
Keith-Weiss 104
PRICING
Rice User Fee: $65/hr
Non-Profit Fee: $101.75/hr
For Profit Fee: $325/hr
Rice Training Fee: $130.00/hr
Non-Profit Training Fee: $203.50/hr
For Profit Training Fee: $650/hr
CONTACTS
Training Contact:
Tanguy Terlier, tanguy.terlier@rice.edu
The required SEA user forms, signed by your advisor, are required before training can be scheduled.
This is a multi-purpose ToF-SIMS system and three different levels of training will be provided:
- The basic level is 4 hours of training, including a detailed introduction of the ToF-SIMS technique and about 2 hours of practice on the spectrometry and imaging.
- The advanced level is about 8 hours of training. Beyond the basic training, the advanced session includes about 2 hours of practice on depth profiling and an initiation of data treatment with ToF-SIMS (spectrum analysis, data calibration …).
- The expert level takes about 12 hours of training. This session is recommended for the users with interest in surface and interfacial analysis of more challenging materials or structures. Expert training introduces the most advanced tools on the instrument such as the combination of ToF-SIMS analysis with in-situ AFM for a 3D reconstruction. The training includes 2 hours of volume render analysis and 1 hour of AFM. An advanced presentation of data treatment with ToF-SIMS (quantification, 3D reconstruction and multivariate analysis …) will be provided.
It is recommended that the training sessions be completed in two weeks. A training certificate will be provided for each level after two to four usages on the instrument. Users with a training certificate can obtain access to the instrument for independent use.
Faculty in Charge:
Rafael Verduzco, rafaelv@rice.edu
DESCRIPTION
Time-of-Flight Secondary Ion Mass Spectrometry is a surface sensitive technique able to obtain both elemental composition and molecular information on a surface and in-depth. ToF-SIMS has the potential to provide detailed insight into the 3D chemical composition. The recent developments in ToF-SIMS such as the development of an argon cluster ion beam and of a tightly focused ion beam ensures high performance for organics (polymer, small molecules) and biological materials. The principle of ToF-SIMS involves detection of secondary ions ejected by the primary ion bombardment. This method enables probing of the chemical composition of surfaces of both inorganic and organic samples. Using ToF-SIMS analysis, it will be possible to achieve directly the molecular and the elemental information of extreme surface for a large mass range (0 – 10,000 a.m.u) for all elements in periodic table and their isotopes, and molecules with high sensitivity (ppm – ppb). The mapping provides highly localized information with a beam spot size of approximately 100 nm and the capability for depth profiling with sub-nm resolution. Together, these techniques provide a 3-D compositional rendering of the sample. The instrument is capable of analyzing inorganic, organic, conductive, and insulating materials. Sample analysis may require the use of standards to quantify signals and deal with mass interferences and to the variation of ionic yields. The ToF-SIMS NCS combines a ToF-SIMS with a Scanning Probe Microscope (SPM). The surface initial topography can be measured as well as the topographic changes during the analysis. SPM information analysis provides complementary information about the surface topography and can also be used to measure the physical properties of the analyzed volume. Through the combination of these both techniques accurate in-situ 3D chemical image becomes possible. ToF-SIMS NCS capabilities: • In-situ Atomic Force Microscope (NanoScan VLS-80) is combined with ToF-SIMS instrument. Topographical analysis can be performed in Contact, Intermittent and Non-Contact scan mode including deflection and phase imaging. • Large mass range spectra are achieved using a pulsed ion beam. The Bi Nanoprobe technology provides SIMS analysis with high-lateral resolution (70 nm) by rastering the field of view in high density of pixels. • Argon Gas Cluster Ion Source is particularly well-adapted for analysis of high mass molecules, preserving a quasi-intact molecular information and with a high sputter yield for in-depth analysis. • Dual Source Column (O2 and Cs) is equipped with two of the most polyvalent ion sources for the analysis of inorganic and organic materials, which permits to detect both, positive and negative, polarities of secondary ions. • Electron flood gun and Oxygen flooding can be used during the analysis, respectively, to compensate the charges and to improve the signal intensity. Both options permit the analysis of any type of materials, conductive or insulating. • Extended Dynamic Range Analysis permits to record intensities of more than 100 ions per pulse per mass with an excellent linearity. • Fast Sample Rotation is a new feature, that helps to, limit the formation of ion beamed induced surface roughening due to the sputtering. • Sample Heating and Cooling option allows the temperature-controlled heating and cooling of the sample under analysis from -130°C to + 600°C with a precision of +/- 1°C. • Transfer Vessel conserves the sample holder (with the samples) from a clean environment, such as a glove box under inert gas atmosphere, to the instrument and vice versa without exposing the sample to ambient air. ToF-SIMS NCS performances: • Surface Spectrometry Full periodic table (including isotopes), plus molecular species (up to 12,000 a.m.u.) Surface Imaging: Depth profiling: 3D Volume Analysis Correlative Analysis with in-situ SPM Retrospective Analysis. Every pixel of an ion image map represents a full mass spectrum. This allows an analysis to retrospectively produce maps for any mass of interest, and to interrogate regions of interest for their chemical composition via computer processing after the dataset has been instrumentally acquired. Schedule rules: 1. Users may only sign up for time starting at 8:30 am, up to two weeks in advance. 2. Users may not reserve more than 8 prime time hours per day. 3. Appointments made within 48 hours of their use do not count against these totals. Note: A data treatment PC for SurfaceLab software is available for use (free-of-charge.) Instrument Rules: Please contact Dr. Tanguy Terlier (tanguy.terlier@rice.edu) to discuss your research needs and to schedule instrument time. Spectrometer time may be reserved on the FOM calendar in accordance with the accompanying document below; if no one else needs to use the spectrometer, you may add to your reserved time period and continue using the spectrometer until someone else does want to use it. Dr. Terlier reserves the right to schedule the instrument as needed for training, specialized work, maintenance, etc. Nonprimetime is 7:00 pm – 8:00 am and weekends. The nonprimetime is only available for routine analysis, automatic measurements and for service. Please consult Rice SIMS Facility staff to discuss about the availability of the nonprimetime schedule and that need to be agreed to prior to being performed. Instrument reservation via FOM calendar Data treatment reservation via Google calendar (online access on SIMS Lab website) Instrument website: http://simslab.blogs.rice.edu